Oregon Scientific RMR383HGA User Manual Page 1

Browse online or download User Manual for Weather stations Oregon Scientific RMR383HGA. Oregon Scientific RMR383HGA User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0

INTRODUCTION
Thank you for selecting this Oregon Scientic
TM
Wireless
Indoor / Outdoor Thermometer with Indoor Humidity and Self-
Setting Atomic clock (RMR383HGA). This clock is supplied
with a remote sensor (THN132N) and can support up to 3
sensors in total (additional sensors sold separately).
NOTE Please keep this manual handy as you use your new
product. It contains practical step-by-step instructions, as well
as technical specications and warnings you should know
about.
CLOCK OVERVIEW
FRONT VIEW
1. SNOOZE
2. Temperature and Humidity Area
3. Clock / Alarm Area
4. ALARM: View alarm status; set alarm
BACK VIEW
1. / : Increase / decrease setting; activate /
deactivate clock reception signal
2. MODE: Change settings / display
3. CHANNEL: Switch remote sensor display
4. MEM: View current, maximum and minimum
temperature / humidity
5. °C / °F: Select temperature unit
6. HEAT INDEX
7. TEMP / HUMIDITY HI / LO : Change settings
or enable / disable hi or lo temperature / humidity
alarm
8. RESET: Reset unit to default settings
9. ZONE: Toggle US time zone
10. Battery compartment
LCD DISPLAY
Temperature and Humidity area:




1. Heat Index icon
2. Hi / lo temperature alarm
3. Max / min temperature icon
4. Sensor reception icon
5. Comfort Zone
6. Battery low icon
7. Hi / lo humidity alarm
8. Max / min humidity icon
9. Ice warning is active
10. Temperature trend
11. Temperature
12. Heat Index warning
13. Humidity
14. Humidity trend
Clock / Alarm area:
1. Clock signal reception
2. AM / PM mode selected
3. Alarm mode
4. Alarm set
5. AM / PM mode selected
6. Alarm time
7. US time zone
8. Clock
9. Moon phase
REMOTE SENSOR (THN132N)
1. LED indicator 1. Wall mount
2. Battery compartment
3. Battery door
4. Table stand
5. RESET
6. CHANNEL switch
GETTING STARTED
BATTERIES
Insert batteries before rst use, matching the polarity (+ and
-). Press RESET after each battery change.
indicates main unit batteries are low.
NOTE Do not use rechargeable batteries. We recommend
that you use alkaline batteries with this product for longer
usage and lithium batteries in temperatures below freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every 40
seconds and sends them to the main unit. The main unit can
collect data from up to 3 sensors.
To set up the sensor:
1. Slide open the battery door.
2. Insert the batteries, matching the polarity (+ / -). Reset
the sensor after each battery change.
3. Select a channel. Make sure you use a different channel
for each sensor.
4. Close the battery compartment.
5. Secure the sensor in the desired location using the wall
mount or table stand.
For best results:
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 30 m (100 ft) from the
main (indoor) unit.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls, and
furniture.
Place the sensor in a location with a clear view to the
sky, away from metallic or electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may affect
battery performance and signal transmission.
The transmission range may vary depending on many factors.
You may need to experiment with various locations to get
the best results.
Standard Alkaline batteries contain signicant amounts of
water. Because of this they will freeze in low temperatures
of approximately -12°C (10°F). Disposable Lithium batteries
have a much lower threshold for temperature with an
estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors
such as extremely cold temperatures. Extreme cold may
temporarily reduce the effective range between the sensor
and the base station. If the unit’s performance fails due to
low temperature, the unit will resume proper functioning as
the temperature rises to within the normal temperature range
(i.e. no permanent damage will occur to the unit due to low
temperatures).
SENSOR DATA TRANSMISSION
The sensor reception icon in the temperature and humidity
area shows the status.
ICON DESCRIPTION
Main unit is searching for the
sensor(s)
A channel has been found and
sensor signal is being received
and “- - . -“ The sensor cannot be found.
(Temperature Search for the sensor or
and Humidity Area) check batteries
To search for a sensor:
Simultaneously, press and hold MEM and CHANNEL for
2 seconds.
NOTE If the sensor is still not found, check the batteries,
obstructions, and remote unit location.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its date and time
automatically once it is within range of the WWVB-60
signal from the atomic clock in Fort Collins, Colorado.
The clock collects the radio signals whenever it is within 3219
km (2000 miles) of a signal.
NOTE Press ZONE to select the US time zone: Pacic (P),
Eastern (E), Central (C) or Mountain (M).
NOTE Initial reception takes 2-10 minutes for rst set up or
when RESET is pressed. Once complete, the reception icon
will stop blinking. If the signal is weak, it can take up to 24
hours to get a valid signal.
RECEPTION SIGNAL
Clock signal reception indicator:
STRONG SIGNAL WEAK SIGNAL NO SIGNAL
To enable and force a signal search:
Press and hold for 2 seconds.
To disable the signal reception:
Press and hold for 2 seconds.
SET CLOCK
If the clock signal reception is enabled and a signal is being
received the clock does not need to be manually set.
To manually set the clock:
1. Press and hold MODE for 2 seconds.
2. Press and to change the settings.
3. Press MODE to conrm.
4. The setting sequence is: 12/24 hour format, hour, minute,
year, date / month format, month, date, and display
language.
Wireless Indoor / Outdoor Thermometer
with Indoor Humidity and
Self-Setting Atomic Clock
Model: RMR383HGA
USER MANUAL
RMR383HGA_M_R6 2006.4.7, 10:19 AM1
Page view 0
1 2

Summary of Contents

Page 1 - USER MANUAL

INTRODUCTIONThank you for selecting this Oregon ScienticTM Wireless Indoor / Outdoor Thermometer with Indoor Humidity and Self-Sett

Page 2 - DECLARATION OF CONFORMITY

NOTE The language options are English (E), German (D), French (F), Italian (I), and Spanish (S).To switch the clock display:Press MODE to toggle betw

Comments to this Manuals

No comments